XRF measures elements, not compounds — so it only answers about 3.5 of the 10 restricted substances. This article provides instructions on how to read results according to three zones (pass - inconclusive - fail), five limits you must know and when you must try to confirm.
Batteries have their own set of regulations with different substance limits than RoHS. The article compares battery limits, other battery regulatory requirements, five things businesses need to do, and five points that are often overlooked.
RoHS and WEEE are often combined into one, but one side regulates substances in products and the other side regulates recall responsibilities. The article compares two sets of regulations and four common misconceptions.
Recycled plastic carries additives from its previous life cycle, making it the most difficult to achieve RoHS. The article outlines the four groups of toxic substances, why testing is difficult, six control steps and the lack of exemptions for recycled materials.
What hot damp testing proves and what it doesn't: four commonly overlooked limits, why 85/85 is not a complete test, what parameters to measure, and how to present the results.
Confirm heat-humidity chamber capacity according to IEC 60068-3-6 and calculate uncertainty according to 60068-3-11: measure stability, uniformity, confirm load, cycle and records to be kept.
The Cx test according to IEC 60068-2-66 uses pressurized unsaturated steam to achieve high temperature and high humidity simultaneously. The article explains the principle, when it is really needed, the procedure for implementation and the safety of pressure chambers.
Cy test according to IEC 60068-2-67: steady heat and humidity form acceleration for components, how is it different from Cab and Cx, why acceleration conditions cannot be used for all products, and steps to perform.
SIOC and Over Boxing are two ISTA 6-AMAZON.COM protocols but opposite in principle: one side has a force-absorbing outer box, the other side does not. The article compares in detail, clarifies where FFP is located, and gives 5 questions to choose the right direction for each product code.
ISTA 6-AMAZON.COM SIOC (Ships In Own Container) is a test for Amazon goods without an outer box: 8 groups of Type A–H, 25 Test Blocks, more rigorous than Over Boxing.
ISTA 7D measures how external temperatures affect transport packaging — heat only, not impact or vibration. The 4-step series and 24/48/72-h winter & summer profiles.
ISTA 6-SAMSCLUB is a Member Performance test for goods entering the Sam's Club system in the US — the four packaging types (A–D) and their test series.
QCVN 19:2025/BKHCN (effective 1 Jun 2026) sets safety and EMC requirements for LED lamps and luminaires; covers the Annex A product list and applicable standards.
In aviation and defense, results are not enough — they must be proven. This article presents the requirements for records, traceability, calibration and change control with cross-section testing.
Void in a BGA solder joint is not automatically a defect. IPC-7095 provides assessment by level, by location and by distribution. This article provides instructions on measuring and reporting void properly.
J-STD-001 specifies process requirements, IPC-A-610 specifies acceptance criteria. This article explains how to use these two standards when reading solder joint cross-sections and the limits to keep in mind.
Two testing laboratories did the same cross-section but gave different results — the cause often lies in the procedure. The article presents the steps to follow and important control points.
QCVN 25:2025/BKHCN sets safety rules for the eight groups of household electrical devices, from socket outlets and plugs to switches, MCBs, RCBOs and RCCBs.
QCVN 4:2009/BKHCN regulates safety requirements for 13 groups of electrical and electronic equipment; Amendment 1:2016 expands the scope to electric wires and cables and changes regulations on certification, registration, and record keeping.